{"_buckets": {"deposit": "dac5d523-392a-4858-94ad-ae9296d4cd07"}, "_deposit": {"created_by": 3, "id": "2478", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "2478"}, "status": "published"}, "_oai": {"id": "oai:kyutech.repo.nii.ac.jp:00002478", "sets": ["24"]}, "author_link": ["8828", "8826", "31450", "8829"], "item_21_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-08", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "720", "bibliographicPageStart": "715", "bibliographicVolumeNumber": "3", "bibliographic_titles": [{"bibliographic_title": "International Symposium on Electromagnetic Compatibility, 2005"}]}]}, "item_21_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "High-speed power line communication (PLC) systems have been developed for home networks. However, the transmission characteristics of an indoor AC mains line have not been clarified. We studied the influence of the appliance operation state on the transmission characteristics of the indoor AC mains line. The AC mains line and appliances were represented by four-port networks and two-port networks. The transmission characteristics were calculated by a model constructed with these networks. The two-port network parameters of the appliances were measured in both operating and stop states. The equivalent circuits were determined for both states based on the condition that the frequency characteristics of the circuits agreed with the measured value. A simple AC mains system was constructed and the transmission characteristics were measured to compare with the calculated value in various states. The results indicate that the calculated value agreed well with the measured one, and the transmission loss deviation resulting from the appliance state was within 10 dB. A common mode choke coil was inserted between the AC mains line and the appliances to reduce the transmission loss deviation resulting from different states. The measured and calculated values indicate that the deviation was reduced from 10 dB to 0.5 dB by inserting the filter.", "subitem_description_type": "Abstract"}]}, "item_21_description_60": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "Journal Article", "subitem_description_type": "Other"}]}, "item_21_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"affiliations": [{"affiliationNames": [{"affiliationName": "", "lang": "ja"}], "nameIdentifiers": []}], "familyNames": [{"familyName": "Kuwabara", "familyNameLang": "en"}, {"familyName": "桑原", "familyNameLang": "ja"}, {"familyName": "クワバラ", "familyNameLang": "ja-Kana"}], "givenNames": [{"givenName": "Nobuo", "givenNameLang": "en"}, {"givenName": "伸夫", "givenNameLang": "ja"}, {"givenName": "ノブオ", "givenNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "31450", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "7005750067", "nameIdentifierScheme": "Scopus著者ID", "nameIdentifierURI": "https://www.scopus.com/authid/detail.uri?authorId=7005750067"}], "names": [{"name": "Kuwabara, Nobuo", "nameLang": "en"}, {"name": "桑原, 伸夫", "nameLang": "ja"}, {"name": "クワバラ, ノブオ", "nameLang": "ja-Kana"}]}]}, "item_21_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Institute of Electrical and Electronics Engineers"}]}, "item_21_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1109/ISEMC.2005.1513617", "subitem_relation_type_select": "DOI"}}]}, "item_21_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "©2005 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE."}]}, "item_21_select_59": {"attribute_name": "査読の有無", "attribute_value_mlt": [{"subitem_select_item": "yes"}]}, "item_21_text_36": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "Fac. of Eng., Kyushu Inst. of Technol."}]}, "item_21_text_64": {"attribute_name": "業績ID", "attribute_value_mlt": [{"subitem_text_value": "4CC860F708EA7DE7492576A2000E6F78"}]}, "item_21_version_type_58": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hirata, D"}], "nameIdentifiers": [{"nameIdentifier": "8826", "nameIdentifierScheme": "WEKO"}]}, {"creatorAffiliations": [{"affiliationNameIdentifiers": [], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "Kuwabara, Nobuo", "creatorNameLang": "en"}, {"creatorName": "桑原, 伸夫", "creatorNameLang": "ja"}, {"creatorName": "クワバラ, ノブオ", "creatorNameLang": "ja-Kana"}], "familyNames": [{"familyName": "Kuwabara", "familyNameLang": "en"}, {"familyName": "桑原", "familyNameLang": "ja"}, {"familyName": "クワバラ", "familyNameLang": "ja-Kana"}], "givenNames": [{"givenName": "Nobuo", "givenNameLang": "en"}, {"givenName": "伸夫", "givenNameLang": "ja"}, {"givenName": "ノブオ", "givenNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "31450", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "7005750067", "nameIdentifierScheme": "Scopus著者ID", "nameIdentifierURI": "https://www.scopus.com/authid/detail.uri?authorId=7005750067"}]}, {"creatorNames": [{"creatorName": "Akiyama, Y"}], "nameIdentifiers": [{"nameIdentifier": "8828", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamane, H"}], "nameIdentifiers": [{"nameIdentifier": "8829", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2010-01-08"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Influence.pdf", "filesize": [{"value": "347.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 347900.0, "url": {"label": "Influence.pdf", "url": "https://kyutech.repo.nii.ac.jp/record/2478/files/Influence.pdf"}, "version_id": "42774816-f983-447e-8dc9-5742dc10fe04"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Influence of appliance state on transmission characteristics of indoor AC mains lines in frequency range used power line communication", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Influence of appliance state on transmission characteristics of indoor AC mains lines in frequency range used power line communication"}]}, "item_type_id": "21", "owner": "3", "path": ["24"], "permalink_uri": "http://hdl.handle.net/10228/3609", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-01-08"}, "publish_date": "2010-01-08", "publish_status": "0", "recid": "2478", "relation": {}, "relation_version_is_last": true, "title": ["Influence of appliance state on transmission characteristics of indoor AC mains lines in frequency range used power line communication"], "weko_shared_id": -1}
Influence of appliance state on transmission characteristics of indoor AC mains lines in frequency range used power line communication
http://hdl.handle.net/10228/3609
http://hdl.handle.net/10228/36090fb83579-5430-423e-97f8-7220f7e12ecc
名前 / ファイル | ライセンス | アクション |
---|---|---|
Influence.pdf (347.9 kB)
|
|
Item type | 学術雑誌論文 = Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-01-08 | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
タイトル | ||||||
タイトル | Influence of appliance state on transmission characteristics of indoor AC mains lines in frequency range used power line communication | |||||
言語 | ||||||
言語 | eng | |||||
著者 |
Hirata, D
× Hirata, D× 桑原, 伸夫× Akiyama, Y× Yamane, H |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | High-speed power line communication (PLC) systems have been developed for home networks. However, the transmission characteristics of an indoor AC mains line have not been clarified. We studied the influence of the appliance operation state on the transmission characteristics of the indoor AC mains line. The AC mains line and appliances were represented by four-port networks and two-port networks. The transmission characteristics were calculated by a model constructed with these networks. The two-port network parameters of the appliances were measured in both operating and stop states. The equivalent circuits were determined for both states based on the condition that the frequency characteristics of the circuits agreed with the measured value. A simple AC mains system was constructed and the transmission characteristics were measured to compare with the calculated value in various states. The results indicate that the calculated value agreed well with the measured one, and the transmission loss deviation resulting from the appliance state was within 10 dB. A common mode choke coil was inserted between the AC mains line and the appliances to reduce the transmission loss deviation resulting from different states. The measured and calculated values indicate that the deviation was reduced from 10 dB to 0.5 dB by inserting the filter. | |||||
書誌情報 |
International Symposium on Electromagnetic Compatibility, 2005 巻 3, p. 715-720, 発行日 2005-08 |
|||||
出版社 | ||||||
出版者 | Institute of Electrical and Electronics Engineers | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1109/ISEMC.2005.1513617 | |||||
著作権関連情報 | ||||||
権利情報 | ©2005 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE. | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
査読の有無 | ||||||
値 | yes | |||||
業績ID | ||||||
4CC860F708EA7DE7492576A2000E6F78 | ||||||
資料タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | Journal Article | |||||
著者別名 | ||||||
姓名 | Kuwabara, Nobuo | |||||
言語 | en | |||||
姓名 | 桑原, 伸夫 | |||||
言語 | ja | |||||
姓名 | クワバラ, ノブオ | |||||
言語 | ja-Kana | |||||
著者所属 | ||||||
Fac. of Eng., Kyushu Inst. of Technol. |