{"_buckets": {"deposit": "146d7742-ea3c-4fc3-9ab0-bdd1fc973213"}, "_deposit": {"created_by": 3, "id": "5986", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "5986"}, "status": "published"}, "_oai": {"id": "oai:kyutech.repo.nii.ac.jp:00005986", "sets": ["24"]}, "author_link": ["24568", "1374", "24567", "1375"], "control_number": "5986", "item_21_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-04-26", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "57560", "bibliographicPageStart": "57550", "bibliographicVolumeNumber": "7", "bibliographic_titles": [{"bibliographic_title": "IEEE Access"}]}]}, "item_21_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Virtual inertia emulation could be regarded as an inevitable component of microgrids with renewable energy, enhancing microgrid inertia and damping properties. In applying this control technique, a phase-locked loop (PLL) is necessary to obtain the estimation of the system frequency data. However, the employment of PLL could cause larger frequency oscillation to the microgrid due to its dynamics. This issue would be exacerbated in a low-inertia microgrid driven by high renewable penetration, severely deteriorating the frequency stability. Thus, the effect of PLL with measurement delay is a critical issue in utilizing the virtual inertia control. To overcome such problem, this paper proposes a robust virtual inertia control for a low-inertia microgrid to minimize the undesirable frequency measurement effects, improving the microgrid frequency stability. The robust H ∞ control design using a linear fractional transformation (LFT) technique is used to develop the virtual inertia control loop, considering the dynamics of PLL with measurement delay and the uncertainties of system inertia and damping. The efficacy of the proposed H ∞ control method is compared to the conventional and optimum proportional-integral (PI)based inertia control. The results show that the H ∞ -based robust virtual inertia control is superior to both conventional virtual inertia control and optimum PI-based virtual inertia control against a wide range of microgrid operating conditions, disturbances, and parametric uncertainties.", "subitem_description_type": "Abstract"}]}, "item_21_description_60": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "Journal Article", "subitem_description_type": "Other"}]}, "item_21_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE"}]}, "item_21_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1109/ACCESS.2019.2913042", "subitem_relation_type_select": "DOI"}}]}, "item_21_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright (c) 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works."}]}, "item_21_select_59": {"attribute_name": "査読の有無", "attribute_value_mlt": [{"subitem_select_item": "yes"}]}, "item_21_source_id_8": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2169-3536", "subitem_source_identifier_type": "PISSN"}]}, "item_21_subject_16": {"attribute_name": "日本十進分類法", "attribute_value_mlt": [{"subitem_subject": "501", "subitem_subject_scheme": "NDC"}]}, "item_21_text_36": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "Department of Electrical and Electronic Engineering, Kyushu Institute of Technology, Kitakyushu, Japan"}, {"subitem_text_value": "Department of Electrical and Electronic Engineering, Kyushu Institute of Technology, Kitakyushu, Japan"}, {"subitem_text_value": "Department of Electrical and Electronic Engineering, Kyushu Institute of Technology, Kitakyushu, Japan"}, {"subitem_text_value": "Department of Electrical and Electronic Engineering, Kyushu Institute of Technology, Kitakyushu, Japan"}]}, "item_21_text_63": {"attribute_name": "連携ID", "attribute_value_mlt": [{"subitem_text_value": "7771"}]}, "item_21_version_type_58": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kerdphol, Thongchart", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "24567", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Rahman, Fathin Saifur", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "24568", "nameIdentifierScheme": "WEKO"}]}, {"creatorAffiliations": [{"affiliationNameIdentifiers": [], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "Watanabe, Masayuki", "creatorNameLang": "en"}, {"creatorName": "渡邊, 政幸", "creatorNameLang": "ja"}, {"creatorName": "ワタナベ, マサユキ", "creatorNameLang": "ja-Kana"}], "familyNames": [{"familyName": "Watanabe", "familyNameLang": "en"}, {"familyName": "渡邊", "familyNameLang": "ja"}, {"familyName": "ワタナベ", "familyNameLang": "ja-Kana"}], "givenNames": [{"givenName": "Masayuki", "givenNameLang": "en"}, {"givenName": "政幸", "givenNameLang": "ja"}, {"givenName": "マサユキ", "givenNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "1374", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "90398115", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000090398115"}, {"nameIdentifier": "55510716600", "nameIdentifierScheme": "Scopus著者ID", "nameIdentifierURI": "https://www.scopus.com/authid/detail.uri?authorId=55510716600"}, {"nameIdentifier": "80", "nameIdentifierScheme": "九工大研究者情報", "nameIdentifierURI": "https://hyokadb02.jimu.kyutech.ac.jp/html/80_ja.html"}]}, {"creatorAffiliations": [{"affiliationNameIdentifiers": [], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "Mitani, Yasunori", "creatorNameLang": "en"}, {"creatorName": "三谷, 康範", "creatorNameLang": "ja"}, {"creatorName": "ミタニ, ヤスノリ", "creatorNameLang": "ja-Kana"}], "familyNames": [{"familyName": "Mitani", "familyNameLang": "en"}, {"familyName": "三谷", "familyNameLang": "ja"}, {"familyName": "ミタニ", "familyNameLang": "ja-Kana"}], "givenNames": [{"givenName": "Yasunori", "givenNameLang": "en"}, {"givenName": "康範", "givenNameLang": "ja"}, {"givenName": "ヤスノリ", "givenNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "1375", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "10192759", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000010192759"}, {"nameIdentifier": "35567465600", "nameIdentifierScheme": "Scopus著者ID", "nameIdentifierURI": "https://www.scopus.com/authid/detail.uri?authorId=35567465600"}, {"nameIdentifier": "59", "nameIdentifierScheme": "九工大研究者情報", "nameIdentifierURI": "https://hyokadb02.jimu.kyutech.ac.jp/html/59_en.html"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-06-13"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ACCESS.2019.2913042.pdf", "filesize": [{"value": "1.7 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1700000.0, "url": {"label": "ACCESS.2019.2913042.pdf", "url": "https://kyutech.repo.nii.ac.jp/record/5986/files/ACCESS.2019.2913042.pdf"}, "version_id": "f7b48dd6-477c-4284-acc4-4155a961fa81"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "frequency stability", "subitem_subject_scheme": "Other"}, {"subitem_subject": "inertia control", "subitem_subject_scheme": "Other"}, {"subitem_subject": "microgrid", "subitem_subject_scheme": "Other"}, {"subitem_subject": "renewable energy", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Robust Virtual Inertia Control of a Low Inertia Microgrid Considering Frequency Measurement Effects", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Robust Virtual Inertia Control of a Low Inertia Microgrid Considering Frequency Measurement Effects", "subitem_title_language": "en"}]}, "item_type_id": "21", "owner": "3", "path": ["24"], "permalink_uri": "http://hdl.handle.net/10228/00007196", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2019-06-13"}, "publish_date": "2019-06-13", "publish_status": "0", "recid": "5986", "relation": {}, "relation_version_is_last": true, "title": ["Robust Virtual Inertia Control of a Low Inertia Microgrid Considering Frequency Measurement Effects"], "weko_shared_id": -1}
Robust Virtual Inertia Control of a Low Inertia Microgrid Considering Frequency Measurement Effects
http://hdl.handle.net/10228/00007196
http://hdl.handle.net/10228/00007196c88b89a3-ddab-48c0-82b1-d5b59738dbbd
名前 / ファイル | ライセンス | アクション |
---|---|---|
ACCESS.2019.2913042.pdf (1.7 MB)
|
|
Item type | 学術雑誌論文 = Journal Article(1) | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2019-06-13 | |||||||||||||||||
資源タイプ | ||||||||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||||||
資源タイプ | journal article | |||||||||||||||||
タイトル | ||||||||||||||||||
言語 | en | |||||||||||||||||
タイトル | Robust Virtual Inertia Control of a Low Inertia Microgrid Considering Frequency Measurement Effects | |||||||||||||||||
言語 | ||||||||||||||||||
言語 | eng | |||||||||||||||||
著者 |
Kerdphol, Thongchart
× Kerdphol, Thongchart× Rahman, Fathin Saifur× 渡邊, 政幸
WEKO
1374
× 三谷, 康範
WEKO
1375
|
|||||||||||||||||
抄録 | ||||||||||||||||||
内容記述タイプ | Abstract | |||||||||||||||||
内容記述 | Virtual inertia emulation could be regarded as an inevitable component of microgrids with renewable energy, enhancing microgrid inertia and damping properties. In applying this control technique, a phase-locked loop (PLL) is necessary to obtain the estimation of the system frequency data. However, the employment of PLL could cause larger frequency oscillation to the microgrid due to its dynamics. This issue would be exacerbated in a low-inertia microgrid driven by high renewable penetration, severely deteriorating the frequency stability. Thus, the effect of PLL with measurement delay is a critical issue in utilizing the virtual inertia control. To overcome such problem, this paper proposes a robust virtual inertia control for a low-inertia microgrid to minimize the undesirable frequency measurement effects, improving the microgrid frequency stability. The robust H ∞ control design using a linear fractional transformation (LFT) technique is used to develop the virtual inertia control loop, considering the dynamics of PLL with measurement delay and the uncertainties of system inertia and damping. The efficacy of the proposed H ∞ control method is compared to the conventional and optimum proportional-integral (PI)based inertia control. The results show that the H ∞ -based robust virtual inertia control is superior to both conventional virtual inertia control and optimum PI-based virtual inertia control against a wide range of microgrid operating conditions, disturbances, and parametric uncertainties. | |||||||||||||||||
書誌情報 |
IEEE Access 巻 7, p. 57550-57560, 発行日 2019-04-26 |
|||||||||||||||||
出版社 | ||||||||||||||||||
出版者 | IEEE | |||||||||||||||||
DOI | ||||||||||||||||||
関連タイプ | isIdenticalTo | |||||||||||||||||
識別子タイプ | DOI | |||||||||||||||||
関連識別子 | https://doi.org/10.1109/ACCESS.2019.2913042 | |||||||||||||||||
日本十進分類法 | ||||||||||||||||||
主題Scheme | NDC | |||||||||||||||||
主題 | 501 | |||||||||||||||||
ISSN | ||||||||||||||||||
収録物識別子タイプ | PISSN | |||||||||||||||||
収録物識別子 | 2169-3536 | |||||||||||||||||
著作権関連情報 | ||||||||||||||||||
権利情報 | Copyright (c) 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. | |||||||||||||||||
キーワード | ||||||||||||||||||
主題Scheme | Other | |||||||||||||||||
主題 | frequency stability | |||||||||||||||||
キーワード | ||||||||||||||||||
主題Scheme | Other | |||||||||||||||||
主題 | inertia control | |||||||||||||||||
キーワード | ||||||||||||||||||
主題Scheme | Other | |||||||||||||||||
主題 | microgrid | |||||||||||||||||
キーワード | ||||||||||||||||||
主題Scheme | Other | |||||||||||||||||
主題 | renewable energy | |||||||||||||||||
出版タイプ | ||||||||||||||||||
出版タイプ | VoR | |||||||||||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||||||||||
査読の有無 | ||||||||||||||||||
値 | yes | |||||||||||||||||
連携ID | ||||||||||||||||||
7771 |