WEKO3
アイテム
Current-Sensor-Less Condition Monitoring of a DC-Link Capacitor Used in a PWM Inverter With a Six-Pulse Diode Rectifier Having AC and DC inductors
http://hdl.handle.net/10228/0002000747
http://hdl.handle.net/10228/0002000747fc7641ce-f0fa-4cb1-93ef-6b2e5d307ef0
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
|
| アイテムタイプ | 学術雑誌論文 = Journal Article(1) | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2024-06-10 | |||||||||||||
| 資源タイプ | ||||||||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||
| 資源タイプ | journal article | |||||||||||||
| タイトル | ||||||||||||||
| タイトル | Current-Sensor-Less Condition Monitoring of a DC-Link Capacitor Used in a PWM Inverter With a Six-Pulse Diode Rectifier Having AC and DC inductors | |||||||||||||
| 言語 | en | |||||||||||||
| 言語 | ||||||||||||||
| 言語 | eng | |||||||||||||
| 著者 |
長谷川, 一徳
× 長谷川, 一徳
WEKO
28366
× Hirose, Yuto
|
|||||||||||||
| 抄録 | ||||||||||||||
| 内容記述タイプ | Abstract | |||||||||||||
| 内容記述 | Condition monitoring plays an important role in improving reliability of power electronic converters including their dc-link capacitors because it contributes to predicting converter failures. This paper presents current-sensor-less condition monitoring of a dc-link capacitor used in a three-phase PWM inverter based on an analysis of the ripple current flowing out of a front-end six-pulse diode rectifier having ac line and dc inductors. The method measures both the capacitance and equivalent-series resistance (ESR) of the capacitor without using current sensors. Theoretical analysis reveals that the capacitor current is calculated by the three-phase ac source voltage, ac line inductor, dc inductor, and output power of the inverter. Experimental results obtained from a 200-V laboratory system confirmed that both the ESR and capacitance changes were observed without any current sensors. | |||||||||||||
| 言語 | en | |||||||||||||
| 書誌情報 |
en : Condition monitoring plays an important role in improving reliability of power electronic converters including their dc-link capacitors because it contributes to predicting converter failures. This paper presents current-sensor-less condition monitoring of a dc-link capacitor used in a three-phase PWM inverter based on an analysis of the ripple current flowing out of a front-end six-pulse diode rectifier having ac line and dc inductors. The method measures both the capacitance and equivalent-series resistance (ESR) of the capacitor without using current sensors. Theoretical analysis reveals that the capacitor current is calculated by the three-phase ac source voltage, ac line inductor, dc inductor, and output power of the inverter. Experimental results obtained from a 200-V laboratory system confirmed that both the ESR and capacitance changes were observed without any current sensors. p. 3707-3710, 発行日 2023-12-29 |
|||||||||||||
| 出版社 | ||||||||||||||
| 出版者 | IEEE | |||||||||||||
| DOI | ||||||||||||||
| 識別子タイプ | DOI | |||||||||||||
| 関連識別子 | https://doi.org/10.1109/ECCE53617.2023.10362014 | |||||||||||||
| ISBN | ||||||||||||||
| 識別子タイプ | ISBN | |||||||||||||
| 関連識別子 | 979-8-3503-1645-2 | |||||||||||||
| ISBN | ||||||||||||||
| 識別子タイプ | ISBN | |||||||||||||
| 関連識別子 | 979-8-3503-1644-5 | |||||||||||||
| ISSN | ||||||||||||||
| 収録物識別子タイプ | PISSN | |||||||||||||
| 収録物識別子 | 2329-3721 | |||||||||||||
| ISSN | ||||||||||||||
| 収録物識別子タイプ | EISSN | |||||||||||||
| 収録物識別子 | 2329-3748 | |||||||||||||
| 出版タイプ | ||||||||||||||
| 出版タイプ | AM | |||||||||||||
| 出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||||||||||
| 査読の有無 | ||||||||||||||
| 値 | yes | |||||||||||||