タイトル Observation of Deformation Process of Elastic Tubes for Pulsatile Flows by Impinging Jet Flows and Its Application to Novel Measurement Method of Blood Pressure
言語 en
著者 Yamamoto, Ayumu

× Yamamoto, Ayumu

en Yamamoto, Ayumu

Search repository
Yanagita, Yoshiki

× Yanagita, Yoshiki

en Yanagita, Yoshiki

Search repository
Miyamura, Yuko

× Miyamura, Yuko

en Miyamura, Yuko

Search repository
Tachibana, Takeshi

× Tachibana, Takeshi

en Tachibana, Takeshi

Search repository
Yamamoto, Yohji

× Yamamoto, Yohji

en Yamamoto, Yohji

Search repository
Kimura, Tetsuya

× Kimura, Tetsuya

en Kimura, Tetsuya

Search repository
玉川, 雅章

× 玉川, 雅章

WEKO 35478
e-Rad_Researcher 80227264
Scopus著者ID 7005691170
ORCiD 0000-0002-5938-346X
九工大研究者情報 315

ja 玉川, 雅章

en Tamagawa, Masaaki

Search repository
抄録
内容記述タイプ Abstract
内容記述 Recently, due to the spreading of COVID-19 infection, non-contact measurement of vital information has been required at hospitals. Conversely, as for the measurement of continuous blood pressure and its fluctuations, it has been more important to find a high risk of diseases earlier. Although most of them are obtained by a mechanical contact sensor based on principle of tonometry, the method cannot be applied to non-contact measurement. In this research, a novel method composed of a jet flow and a camera for measuring blood pressure without contact is proposed, and continuous blood pressure and its fluctuations can be detected by this method. In this paper, to develop this novel method, a blood arterial is simulated as an elastic tube, and the deformation process of the elastic tube is observed under pulsatile flow, and the relationship between the deformation process and blood pressure will be obtained. In the experiments, a silicone tube is used to simulate a blood vessel, and the fluid is circulated by a roller pump to create a pulsatile flow. The jet flow is targeted to the tube surface from a nozzle from 0 to 0.37 MPa, and internal pressure in the tube is measured by a pressure sensor. As a result, the displacement and the internal pressure of the tube increased rapidly when a jet flow of a certain pressure was targeted to the tube surface. In addition, it was confirmed that a gradient of cross-sectional area of the tube with the jet pressure reached to inflection point when the internal pressure increased rapidly. Therefore, there is a possibility that jet pressure applicable to blood pressure measurement can be estimated from the gradient change of the cross-sectional area.
言語 en
書誌情報 en : Journal of Advanced Research in Fluid Mechanics and Thermal Sciences

巻 119, 号 2, p. 149-159, 発行日 2024-07-30
出版社
出版者 Semarak Ilmu Publishing
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
DOI
識別子タイプ DOI
関連識別子 https://doi.org/10.37934/arfmts.119.2.149159
ISSN
収録物識別子タイプ EISSN
収録物識別子 2289-7879
査読の有無
値 yes
研究者情報
URL https://hyokadb02.jimu.kyutech.ac.jp/html/315_ja.html
論文ID(連携)
値 10443842
連携ID
値 12572
戻る
0
views
See details
Views

Versions

Ver.1 2025-01-30 07:33:00.371106
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3