| アイテムタイプ |
共通アイテムタイプ(1) |
| 公開日 |
2025-04-04 |
| タイトル |
|
|
タイトル |
Fundamental Investigation on Contactless and Continuous Blood Pressure Measurement by Impinging Jet Flow and Imaging Photoplethysmography |
|
言語 |
en |
| その他のタイトル |
|
|
その他のタイトル |
FUNDAMENTAL INVESTIGATION ON CONTACTLESS AND CONTINUOUS BLOOD PRESSURE MEASUREMENT BY IMPINGING JET FLOW AND IMAGING PHOTOPLETHYSMOGRAPHY |
|
言語 |
en |
| 著者 |
Yamamoto, Ayumu
Taoka, Kota
Hirakawa, Koh
Yanagita, Yoshiki
Miyamura, Yuko
Yamamoto, Yohji
Tachibana, Takeshi
Kimura, Tetsuya
玉川, 雅章
|
| 著作権関連情報 |
|
|
権利情報 |
ICIC International Copyright (c) 2025 |
|
言語 |
en |
| 抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
Due to the recent COVID-19 infection spreading, contactless measurement of vital information has been required at hospitals. On the other hand, as for measurement of continuous blood pressure (BP) and its fluctuations, it has been more important to find a high risk of diseases earlier. Although most of them are obtained by a mechanical contact sensor based on principle of tonometry, we have proposed a novel method by ejecting jet flow and a camera for measuring BP without contact, which can detect continuous BP and its fluctuations. However, it has not been confirmed yet whether the continuous measurement of blood pressure is possible or not in our previous investigations. In this study, to develop this contactless and continuous BP measurement system that uses the deformation of blood vessels, effects of the jet timing and pulse duration on the behaviour of the pulsating elastic tube are investigated. In the experiments, a silicon tube is used to simulate a blood vessel, and the fluid is circulated as a pulsatile flow. The jet flow is ejected from a nozzle to the tube surface, and internal pressure is measured by a pressure sensor. From comparing the internal pressure with displacement of elastic tube surface, it was concluded that 1) it is possible to control jet pressure that does not affect the internal pressure in the tube, 2) it was suggested that the averaged displacement by impinging jet flow follows the averaged internal pressure in the tube at the same time, and 3) internal pressure measurement by short duration time of jet pulses can be applied to continuous BP measurement. |
|
言語 |
en |
| 書誌情報 |
en : ICIC Express Letters: An international journal of research and surveys
巻 19,
号 5,
p. 527-534,
発行日 2025-05
|
| 出版社 |
|
|
出版者 |
ICIC International |
| キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Blood pressure |
| キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Contactless measurement |
| キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Continuous measurement |
| キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Impinging jet flow |
| キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Imaging photoplethysmography |
| 言語 |
|
|
言語 |
eng |
| 資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
journal article |
| 出版タイプ |
|
|
出版タイプ |
VoR |
|
出版タイプResource |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| DOI |
|
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
https://doi.org/10.24507/icicel.19.05.527 |
| 助成情報 |
|
|
|
助成機関名 |
Kitakyushu Foundation for the Advancement of Industry, Science and Technology (FAIS) |
|
|
言語 |
en |
| ISSN |
|
|
収録物識別子タイプ |
PISSN |
|
収録物識別子 |
1881-803X |
| 研究者情報 |
|
|
URL |
https://hyokadb02.jimu.kyutech.ac.jp/html/315_ja.html |
| 論文ID(連携) |
|
|
値 |
10450123 |
| 連携ID |
|
|
値 |
14277 |