{"created":"2023-05-15T11:57:01.518413+00:00","id":2478,"links":{},"metadata":{"_buckets":{"deposit":"dac5d523-392a-4858-94ad-ae9296d4cd07"},"_deposit":{"created_by":3,"id":"2478","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"2478"},"status":"published"},"_oai":{"id":"oai:kyutech.repo.nii.ac.jp:00002478","sets":["8:24"]},"author_link":["8828","8826","31450","8829"],"item_21_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-08","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"720","bibliographicPageStart":"715","bibliographicVolumeNumber":"3","bibliographic_titles":[{"bibliographic_title":"International Symposium on Electromagnetic Compatibility, 2005"}]}]},"item_21_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"High-speed power line communication (PLC) systems have been developed for home networks. However, the transmission characteristics of an indoor AC mains line have not been clarified. We studied the influence of the appliance operation state on the transmission characteristics of the indoor AC mains line. The AC mains line and appliances were represented by four-port networks and two-port networks. The transmission characteristics were calculated by a model constructed with these networks. The two-port network parameters of the appliances were measured in both operating and stop states. The equivalent circuits were determined for both states based on the condition that the frequency characteristics of the circuits agreed with the measured value. A simple AC mains system was constructed and the transmission characteristics were measured to compare with the calculated value in various states. The results indicate that the calculated value agreed well with the measured one, and the transmission loss deviation resulting from the appliance state was within 10 dB. A common mode choke coil was inserted between the AC mains line and the appliances to reduce the transmission loss deviation resulting from different states. The measured and calculated values indicate that the deviation was reduced from 10 dB to 0.5 dB by inserting the filter.","subitem_description_type":"Abstract"}]},"item_21_description_60":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Journal Article","subitem_description_type":"Other"}]},"item_21_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"affiliations":[{"affiliationNames":[{"affiliationName":"","lang":"ja"}],"nameIdentifiers":[]}],"familyNames":[{"familyName":"Kuwabara","familyNameLang":"en"},{"familyName":"桑原","familyNameLang":"ja"},{"familyName":"クワバラ","familyNameLang":"ja-Kana"}],"givenNames":[{"givenName":"Nobuo","givenNameLang":"en"},{"givenName":"伸夫","givenNameLang":"ja"},{"givenName":"ノブオ","givenNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"31450","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"7005750067","nameIdentifierScheme":"Scopus著者ID","nameIdentifierURI":"https://www.scopus.com/authid/detail.uri?authorId=7005750067"}],"names":[{"name":"Kuwabara, Nobuo","nameLang":"en"},{"name":"桑原, 伸夫","nameLang":"ja"},{"name":"クワバラ, ノブオ","nameLang":"ja-Kana"}]}]},"item_21_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Institute of Electrical and Electronics Engineers"}]},"item_21_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1109/ISEMC.2005.1513617","subitem_relation_type_select":"DOI"}}]},"item_21_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"©2005 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE."}]},"item_21_select_59":{"attribute_name":"査読の有無","attribute_value_mlt":[{"subitem_select_item":"yes"}]},"item_21_text_36":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"Fac. of Eng., Kyushu Inst. of Technol."}]},"item_21_text_64":{"attribute_name":"業績ID","attribute_value_mlt":[{"subitem_text_value":"4CC860F708EA7DE7492576A2000E6F78"}]},"item_21_version_type_58":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hirata, D"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"Kuwabara, Nobuo","creatorNameLang":"en"},{"creatorName":"桑原, 伸夫","creatorNameLang":"ja"},{"creatorName":"クワバラ, ノブオ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Akiyama, Y"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yamane, H"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2010-01-08"}],"displaytype":"detail","filename":"Influence.pdf","filesize":[{"value":"347.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Influence.pdf","url":"https://kyutech.repo.nii.ac.jp/record/2478/files/Influence.pdf"},"version_id":"42774816-f983-447e-8dc9-5742dc10fe04"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Influence of appliance state on transmission characteristics of indoor AC mains lines in frequency range used power line communication","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Influence of appliance state on transmission characteristics of indoor AC mains lines in frequency range used power line communication"}]},"item_type_id":"21","owner":"3","path":["24"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-01-08"},"publish_date":"2010-01-08","publish_status":"0","recid":"2478","relation_version_is_last":true,"title":["Influence of appliance state on transmission characteristics of indoor AC mains lines in frequency range used power line communication"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-10-25T09:50:07.018240+00:00"}