{"created":"2023-05-15T11:55:23.876276+00:00","id":305,"links":{},"metadata":{"_buckets":{"deposit":"652636c9-1d0a-4c48-8efe-6782f4261a7d"},"_deposit":{"created_by":3,"id":"305","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"305"},"status":"published"},"_oai":{"id":"oai:kyutech.repo.nii.ac.jp:00000305","sets":["8:24"]},"author_link":["1542","1541","1375"],"control_number":"305","item_21_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1987-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"544","bibliographicPageStart":"541","bibliographicVolumeNumber":"23","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Magnetics"}]}]},"item_21_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper presents the experimental results of stabilization of a model power transmission system by using a Superconducting Magnet Energy Storage (SMES). The SMES, which was composed of two sets of GTO (Gate Turn Off thyristor) power converters and a superconducting coil, is capable of controlling active power (P) and reactive power (Q) simultaneously in four quadrants by changing the firing angles of power converters. The model power transmission system was designed to simulate the behavior of a real scale long distance bulk power transmission system with voltage of 500 kV, capacity of 2000 MVA and length of 280 km. In this study, we have experimented power system stabilizing control by applying P-Q simultaneous control ability of SMES. From the results of experiment it was demonstrated that stabilizing effect by means of SMES is very significant.","subitem_description_type":"Abstract"}]},"item_21_description_60":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Journal Article","subitem_description_type":"Other"}]},"item_21_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"affiliations":[{"affiliationNames":[{"affiliationName":"","lang":"ja"}],"nameIdentifiers":[]}],"familyNames":[{"familyName":"Mitani","familyNameLang":"en"},{"familyName":"三谷","familyNameLang":"ja"},{"familyName":"ミタニ","familyNameLang":"ja-Kana"}],"givenNames":[{"givenName":"Yasunori","givenNameLang":"en"},{"givenName":"康範","givenNameLang":"ja"},{"givenName":"ヤスノリ","givenNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"1375","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"10192759","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://nrid.nii.ac.jp/ja/nrid/1000010192759"},{"nameIdentifier":"35567465600","nameIdentifierScheme":"Scopus著者ID","nameIdentifierURI":"https://www.scopus.com/authid/detail.uri?authorId=35567465600"},{"nameIdentifier":"59","nameIdentifierScheme":"九工大研究者情報","nameIdentifierURI":"https://hyokadb02.jimu.kyutech.ac.jp/html/59_en.html"}],"names":[{"name":"Mitani, Yasunori","nameLang":"en"},{"name":"三谷, 康範","nameLang":"ja"},{"name":"ミタニ, ヤスノリ","nameLang":"ja-Kana"}]}]},"item_21_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Institute of Electrical and Electronics Engineers"}]},"item_21_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/TMAG.1987.1064898","subitem_relation_type_select":"DOI"}}]},"item_21_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"©1987 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE."}]},"item_21_select_59":{"attribute_name":"査読の有無","attribute_value_mlt":[{"subitem_select_item":"yes"}]},"item_21_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0018-9464","subitem_source_identifier_type":"PISSN"}]},"item_21_text_36":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"Osaka University, Osaka, Japan (Kyushu Institute of Technology, Fukuoka, Japan)"},{"subitem_text_value":"Osaka University, Osaka, Japan"},{"subitem_text_value":"Osaka University, Osaka, Japan"}]},"item_21_version_type_58":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"Mitani, Yasunori","creatorNameLang":"en"},{"creatorName":"三谷, 康範","creatorNameLang":"ja"},{"creatorName":"ミタニ, ヤスノリ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Murakami, Y","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tsuji, K","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2007-12-25"}],"displaytype":"detail","filename":"1987-3-ASC.pdf","filesize":[{"value":"284.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"1987-3-ASC.pdf","url":"https://kyutech.repo.nii.ac.jp/record/305/files/1987-3-ASC.pdf"},"version_id":"73751c82-ae52-44c5-b4f9-93b9e84a4b27"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Experimental study on stabilization of model power transmission system by using four quadrant active and reactive power control by SMES","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Experimental study on stabilization of model power transmission system by using four quadrant active and reactive power control by SMES","subitem_title_language":"en"}]},"item_type_id":"21","owner":"3","path":["24"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2007-12-25"},"publish_date":"2007-12-25","publish_status":"0","recid":"305","relation_version_is_last":true,"title":["Experimental study on stabilization of model power transmission system by using four quadrant active and reactive power control by SMES"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2024-04-26T02:08:38.571453+00:00"}