{"created":"2023-05-15T11:55:24.411548+00:00","id":318,"links":{},"metadata":{"_buckets":{"deposit":"b0967cef-efc1-4298-a73f-badb7e98c69d"},"_deposit":{"created_by":3,"id":"318","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"318"},"status":"published"},"_oai":{"id":"oai:kyutech.repo.nii.ac.jp:00000318","sets":["8:9"]},"author_link":["1596","1375","1595","1374","1599"],"control_number":"318","item_1689815586683":{"attribute_name":"CRID","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://cir.nii.ac.jp/crid/1050564288863123200","subitem_relation_type_select":"URI"}}]},"item_21_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"2368","bibliographicPageStart":"2365","bibliographicVolumeNumber":"17","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Applied Superconductivity","bibliographic_titleLang":"en"}]}]},"item_21_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper presents the use of superconducting magnetic energy storage (SMES) with robust controllers for stabilization of tie-line power flow in a longitudinally interconnected power system with wind farms. The high penetration of wind power with abrupt changes causes fluctuations of tie-line power flow and significantly affects the effective use of transmission lines. A simultaneous active and reactive power control scheme of SMES including a characteristic of SMES coil current is employed for realizing a permissible range of SMES operation. Moreover, a multiplicative uncertainty model is considered in the parameter optimization of robust SMES controllers by using a heuristic method. Finally, simulation results are carried out to show the effectiveness and robustness under various situations.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_21_publisher_7":{"attribute_name":"出版社","attribute_value_mlt":[{"subitem_publisher":"IEEE"}]},"item_21_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/TASC.2007.897846","subitem_relation_type_select":"DOI"}}]},"item_21_rights_13":{"attribute_name":"著作権関連情報","attribute_value_mlt":[{"subitem_rights":"Copyright (c) 2007 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE."}]},"item_21_select_59":{"attribute_name":"査読の有無","attribute_value_mlt":[{"subitem_select_item":"yes"}]},"item_21_source_id_10":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA10791666","subitem_source_identifier_type":"NCID"}]},"item_21_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1558-2515","subitem_source_identifier_type":"EISSN"},{"subitem_source_identifier":"1051-8223","subitem_source_identifier_type":"PISSN"}]},"item_21_subject_16":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"427","subitem_subject_scheme":"NDC"}]},"item_21_version_type_58":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Dechanupaprittha, Sanchai","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hongesombut, Sanchai","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNames":[{}]}],"creatorNames":[{"creatorName":"Watanabe, Masayuki","creatorNameLang":"en"},{"creatorName":"渡邊, 政幸","creatorNameLang":"ja"},{"creatorName":"ワタナベ, マサユキ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{},{},{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"Mitani, Yasunori","creatorNameLang":"en"},{"creatorName":"三谷, 康範","creatorNameLang":"ja"},{"creatorName":"ミタニ, ヤスノリ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Ngamroo, Issarachai","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2007-12-25"}],"displaytype":"detail","filename":"2007-6-ASC_Sanchai.pdf","filesize":[{"value":"474.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"2007-6-ASC_Sanchai.pdf","url":"https://kyutech.repo.nii.ac.jp/record/318/files/2007-6-ASC_Sanchai.pdf"},"version_id":"51a618c8-5b0c-4796-abe7-7c45f4dee1bc"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Stabilization of Tie-Line Power Flow by Robust SMES Controller for Interconnected Power System With Wind Farms","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Stabilization of Tie-Line Power Flow by Robust SMES Controller for Interconnected Power System With Wind Farms","subitem_title_language":"en"}]},"item_type_id":"21","owner":"3","path":["9"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2007-12-25"},"publish_date":"2007-12-25","publish_status":"0","recid":"318","relation_version_is_last":true,"title":["Stabilization of Tie-Line Power Flow by Robust SMES Controller for Interconnected Power System With Wind Farms"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2024-04-26T02:08:40.756587+00:00"}