{"created":"2023-05-15T11:55:25.288016+00:00","id":339,"links":{},"metadata":{"_buckets":{"deposit":"83a5c33a-e510-45dc-8936-c41af34ff8b4"},"_deposit":{"created_by":3,"id":"339","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"339"},"status":"published"},"_oai":{"id":"oai:kyutech.repo.nii.ac.jp:00000339","sets":["8:9"]},"author_link":["1717","1718","1719","1720","1721","5959","1723","1724","1725"],"control_number":"339","item_1689815586683":{"attribute_name":"CRID","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://cir.nii.ac.jp/crid/1050564288863132032","subitem_relation_type_select":"URI"}}]},"item_21_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"819","bibliographicPageStart":"816","bibliographicVolumeNumber":"17","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Applied Superconductivity","bibliographic_titleLang":"en"}]}]},"item_21_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have developed a magnetic immunoassay system utilizing a magnetic marker and HTS SQUID. In this system, the magnetic marker was used to detect the biological material called antigen. The magnetic marker was designed so as to generate a remanence, and the remanence field of the markers that bound to the antigens was measured with the SQUID. The measurement was performed in a solution that contained both the bound and free (or unbound) markers, i.e., without using the so-called bound/free (BF) separation process. The Brownian rotation of the free markers in the solution was used to distinguish the bound markers from the free ones. Using the system, we conducted the detection of the biological material called human IgE. Good relationship was obtained between the detected signal and the weight of IgE. Minimum detectable weight of IgE was 2.4 pg (or 15 atto-mol). This sensitivity was limited by the background signal from the free markers.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_21_publisher_7":{"attribute_name":"出版社","attribute_value_mlt":[{"subitem_publisher":"IEEE"}]},"item_21_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/TASC.2007.897699","subitem_relation_type_select":"DOI"}}]},"item_21_rights_13":{"attribute_name":"著作権関連情報","attribute_value_mlt":[{"subitem_rights":"©2007 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE."}]},"item_21_select_59":{"attribute_name":"査読の有無","attribute_value_mlt":[{"subitem_select_item":"yes"}]},"item_21_source_id_10":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA10791666","subitem_source_identifier_type":"NCID"}]},"item_21_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1558-2515","subitem_source_identifier_type":"EISSN"},{"subitem_source_identifier":"1051-8223","subitem_source_identifier_type":"PISSN"}]},"item_21_subject_16":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"492","subitem_subject_scheme":"NDC"}]},"item_21_version_type_58":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Enpuku, K","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nishimoto, T","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Matsuda, T","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tokumitsu, H","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tanaka, T","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNames":[{}]}],"creatorNames":[{"creatorName":"Yoshinaga, Kohji","creatorNameLang":"en"},{"creatorName":"吉永, 耕二","creatorNameLang":"ja"},{"creatorName":"ヨシナガ, コウジ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kuma, I","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hamasaki, N","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Soejima, K","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2007-12-27"}],"displaytype":"detail","filename":"TASC.2007.897699.pdf","filesize":[{"value":"151.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"TASC.2007.897699.pdf","url":"https://kyutech.repo.nii.ac.jp/record/339/files/TASC.2007.897699.pdf"},"version_id":"113d5c96-efa9-4aa8-939b-4b2259ca697f"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Biological Immunoassays Without Bound/Free Separation Utilizing Magnetic Marker and HTS SQUID","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Biological Immunoassays Without Bound/Free Separation Utilizing Magnetic Marker and HTS SQUID","subitem_title_language":"en"}]},"item_type_id":"21","owner":"3","path":["9"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2007-12-27"},"publish_date":"2007-12-27","publish_status":"0","recid":"339","relation_version_is_last":true,"title":["Biological Immunoassays Without Bound/Free Separation Utilizing Magnetic Marker and HTS SQUID"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2024-04-02T08:42:25.933761+00:00"}