{"created":"2023-05-15T11:58:36.908207+00:00","id":4693,"links":{},"metadata":{"_buckets":{"deposit":"6d827482-a397-4234-b6b5-51e08eb5d8b0"},"_deposit":{"created_by":3,"id":"4693","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"4693"},"status":"published"},"_oai":{"id":"oai:kyutech.repo.nii.ac.jp:00004693","sets":["8:24"]},"author_link":["17047","17054"],"item_21_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2015-02-20","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"59","bibliographicPageStart":"55","bibliographicVolumeNumber":"4","bibliographic_titles":[{"bibliographic_title":"Advanced Biomedical Engineering"}]}]},"item_21_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In this study, we proposed and examined the evaluation method for image processing of capillary vessels in the fingertips. Objectification of an image has many problems; especially, it is difficult to evaluate meandering of a blood vessel. Therefore we extracted the vessel shape from a clinical image, and simplified it to numeric data representing the characteristics of the shape. Using clinical illustration of the nailfold capillary, we investigated the characteristics of the nailfold capillary by feature point extraction techniques. We created a simplified program that automatically calculates the parameters of fingertip blood vessels from clinical images. This technique may be potentially useful to evaluate the status of capillaries after intake of supplements, by measuring the parameters of the microcapillary shape.","subitem_description_type":"Abstract"}]},"item_21_description_60":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Journal Article","subitem_description_type":"Other"}]},"item_21_link_62":{"attribute_name":"研究者情報","attribute_value_mlt":[{"subitem_link_url":"https://hyokadb02.jimu.kyutech.ac.jp/html/256_ja.html"}]},"item_21_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"社団法人日本生体医工学会"}]},"item_21_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"info:doi/10.14326/abe.4.55","subitem_relation_type_select":"DOI"}}]},"item_21_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"日本生体医工学会"}]},"item_21_select_59":{"attribute_name":"査読の有無","attribute_value_mlt":[{"subitem_select_item":"yes"}]},"item_21_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2187-5219","subitem_source_identifier_type":"ISSN"}]},"item_21_text_36":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"Kyushu Institute of Technology"},{"subitem_text_value":"Juntendo University"}]},"item_21_text_63":{"attribute_name":"連携ID","attribute_value_mlt":[{"subitem_text_value":"5791"}]},"item_21_version_type_58":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"Nagayama, Katsuya","creatorNameLang":"en"},{"creatorName":"永山, 勝也","creatorNameLang":"ja"},{"creatorName":"ナガヤマ, カツヤ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Miura, Ichiro"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-11-25"}],"displaytype":"detail","filename":"ABE4_55.pdf","filesize":[{"value":"818.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ABE4_55.pdf","url":"https://kyutech.repo.nii.ac.jp/record/4693/files/ABE4_55.pdf"},"version_id":"5030f12c-dac1-4d8d-aac9-ec8be2a0a4dd"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"microscope","subitem_subject_scheme":"Other"},{"subitem_subject":"nailfold capillary","subitem_subject_scheme":"Other"},{"subitem_subject":"image processing","subitem_subject_scheme":"Other"},{"subitem_subject":"radar chart","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Quantification Method of Vascular Conditions by Capillaroscopy","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Quantification Method of Vascular Conditions by Capillaroscopy"}]},"item_type_id":"21","owner":"3","path":["24"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-11-25"},"publish_date":"2016-11-25","publish_status":"0","recid":"4693","relation_version_is_last":true,"title":["Quantification Method of Vascular Conditions by Capillaroscopy"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-10-25T09:10:15.176663+00:00"}