{"created":"2023-05-15T11:58:47.461895+00:00","id":4956,"links":{},"metadata":{"_buckets":{"deposit":"0d9f5f69-ecf9-44b0-93de-8c790eab83e5"},"_deposit":{"created_by":3,"id":"4956","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"4956"},"status":"published"},"_oai":{"id":"oai:kyutech.repo.nii.ac.jp:00004956","sets":["8:24"]},"author_link":["19931","19938","19937","19930","19935","17343","19936","19934","19932"],"item_21_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-03-30","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"580","bibliographicPageStart":"578","bibliographicVolumeNumber":"30","bibliographic_titles":[{"bibliographic_title":"Journal of the Magnetics Society of Japan"}]}]},"item_21_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Polarization modulation technique has been applied for magneto-optical (MO) imaging to measure MO values quantitatively. In this paper, we report on a real-time MO imaging using the polarization modulation method with a liquid crystal modulator. Measurements of MO images and hysteresis Kerr loop of patterned Bi,Ga substituted yttrium iron garnet film were demonstrated by using the technique. A frame rate of 1 s was achieved in this experiment.","subitem_description_type":"Abstract"}]},"item_21_description_60":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Journal Article","subitem_description_type":"Other"}]},"item_21_link_62":{"attribute_name":"研究者情報","attribute_value_mlt":[{"subitem_link_url":"https://hyokadb02.jimu.kyutech.ac.jp/html/100000669_ja.html"}]},"item_21_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"公益社団法人日本磁気学会"}]},"item_21_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"info:doi/10.3379/jmsjmag.30.578","subitem_relation_type_select":"DOI"}}]},"item_21_relation_14":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://doi.org/10.3379/jmsjmag.30.578"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.3379/jmsjmag.30.578","subitem_relation_type_select":"DOI"}}]},"item_21_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright (c) 2006 by The Magnetics Society of Japan"}]},"item_21_select_59":{"attribute_name":"査読の有無","attribute_value_mlt":[{"subitem_select_item":"yes"}]},"item_21_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12297999","subitem_source_identifier_type":"NCID"}]},"item_21_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1882-2924","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"1882-2932","subitem_source_identifier_type":"ISSN"}]},"item_21_text_28":{"attribute_name":"論文ID(連携)","attribute_value_mlt":[{"subitem_text_value":"10270726"}]},"item_21_text_36":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"Institute of Symbiotic Science and Technology, Tokyo University of Agriculture and Technology"},{"subitem_text_value":"Institute of Symbiotic Science and Technology, Tokyo University of Agriculture and Technology"},{"subitem_text_value":"Institute of Symbiotic Science and Technology, Tokyo University of Agriculture and Technology"},{"subitem_text_value":"Institute of Symbiotic Science and Technology, Tokyo University of Agriculture and Technology"},{"subitem_text_value":"Institute of Symbiotic Science and Technology, Tokyo University of Agriculture and Technology"},{"subitem_text_value":"Institute of Symbiotic Science and Technology, Tokyo University of Agriculture and Technology"},{"subitem_text_value":"Neoark Corporation"},{"subitem_text_value":"Neoark Corporation"},{"subitem_text_value":"Institute of Symbiotic Science and Technology, Tokyo University of Agriculture and Technology"}]},"item_21_text_63":{"attribute_name":"連携ID","attribute_value_mlt":[{"subitem_text_value":"5956"}]},"item_21_version_type_58":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ishibashi, T."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yufune, S."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kawata, T."}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"Oda, Masaru","creatorNameLang":"en"},{"creatorName":"小田, 勝","creatorNameLang":"ja"},{"creatorName":"オダ, マサル","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Tani, T."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Iimura, Y."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Konishi, Y."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Akahane, K."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Sato, K."}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-05-08"}],"displaytype":"detail","filename":"JMS-36-6-578.pdf","filesize":[{"value":"535.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"JMS-36-6-578.pdf","url":"https://kyutech.repo.nii.ac.jp/record/4956/files/JMS-36-6-578.pdf"},"version_id":"f11b94d5-e62a-4dde-b499-19b9f6a2319b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"magneto-optical imaging","subitem_subject_scheme":"Other"},{"subitem_subject":"garnet thin film","subitem_subject_scheme":"Other"},{"subitem_subject":"real time measurement","subitem_subject_scheme":"Other"},{"subitem_subject":"liquid crystal modulator","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Real Time Magneto-optical Imaging using Liquid Crystal Modulator","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Real Time Magneto-optical Imaging using Liquid Crystal Modulator"}]},"item_type_id":"21","owner":"3","path":["24"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-05-08"},"publish_date":"2017-05-08","publish_status":"0","recid":"4956","relation_version_is_last":true,"title":["Real Time Magneto-optical Imaging using Liquid Crystal Modulator"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-10-25T08:15:52.641461+00:00"}