{"created":"2023-05-15T11:58:47.461895+00:00","id":4956,"links":{},"metadata":{"_buckets":{"deposit":"6a123703-3783-4447-a308-0be142ad7457"},"_deposit":{"created_by":3,"id":"4956","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"4956"},"status":"published"},"_oai":{"id":"oai:kyutech.repo.nii.ac.jp:00004956","sets":["8:24"]},"author_link":["19930","19931","19932","17343","19934","19935","19936","19937","19938"],"control_number":"4956","item_21_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-03-30","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"580","bibliographicPageStart":"578","bibliographicVolumeNumber":"30","bibliographic_titles":[{"bibliographic_title":"Journal of the Magnetics Society of Japan","bibliographic_titleLang":"en"}]}]},"item_21_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Polarization modulation technique has been applied for magneto-optical (MO) imaging to measure MO values quantitatively. In this paper, we report on a real-time MO imaging using the polarization modulation method with a liquid crystal modulator. Measurements of MO images and hysteresis Kerr loop of patterned Bi,Ga substituted yttrium iron garnet film were demonstrated by using the technique. A frame rate of 1 s was achieved in this experiment.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_21_link_62":{"attribute_name":"研究者情報","attribute_value_mlt":[{"subitem_link_text":"https://hyokadb02.jimu.kyutech.ac.jp/html/100000669_ja.html","subitem_link_url":"https://hyokadb02.jimu.kyutech.ac.jp/html/100000669_ja.html"}]},"item_21_publisher_7":{"attribute_name":"出版社","attribute_value_mlt":[{"subitem_publisher":"日本磁気学会","subitem_publisher_language":"ja"}]},"item_21_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.3379/jmsjmag.30.578","subitem_relation_type_select":"DOI"}}]},"item_21_rights_13":{"attribute_name":"著作権関連情報","attribute_value_mlt":[{"subitem_rights":"Copyright (c) 2006 by The Magnetics Society of Japan"}]},"item_21_select_59":{"attribute_name":"査読の有無","attribute_value_mlt":[{"subitem_select_item":"yes"}]},"item_21_source_id_10":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA12297999","subitem_source_identifier_type":"NCID"}]},"item_21_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1882-2924","subitem_source_identifier_type":"PISSN"},{"subitem_source_identifier":"1882-2932","subitem_source_identifier_type":"EISSN"}]},"item_21_text_28":{"attribute_name":"論文ID(連携)","attribute_value_mlt":[{"subitem_text_value":"10270726"}]},"item_21_text_63":{"attribute_name":"連携ID","attribute_value_mlt":[{"subitem_text_value":"5956"}]},"item_21_version_type_58":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ishibashi, T.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"19930","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yufune, S.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"19931","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kawata, T.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"19932","nameIdentifierScheme":"WEKO"}]},{"creatorAffiliations":[{"affiliationNames":[{"affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"Oda, Masaru","creatorNameLang":"en"},{"creatorName":"小田, 勝","creatorNameLang":"ja"},{"creatorName":"オダ, マサル","creatorNameLang":"ja-Kana"}],"familyNames":[{"familyName":"Oda","familyNameLang":"en"},{"familyName":"小田","familyNameLang":"ja"},{"familyName":"オダ","familyNameLang":"ja-Kana"}],"givenNames":[{"givenName":"Masaru","givenNameLang":"en"},{"givenName":"勝","givenNameLang":"ja"},{"givenName":"マサル","givenNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"17343","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"30345334","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://nrid.nii.ac.jp/ja/nrid/1000030345334"},{"nameIdentifier":"7402781061","nameIdentifierScheme":"Scopus著者ID","nameIdentifierURI":"https://www.scopus.com/authid/detail.uri?authorId=7402781061"},{"nameIdentifier":"100000669","nameIdentifierScheme":"九工大研究者情報","nameIdentifierURI":"https://hyokadb02.jimu.kyutech.ac.jp/html/100000669_ja.html"}]},{"creatorNames":[{"creatorName":"Tani, T.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"19934","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Iimura, Y.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"19935","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Konishi, Y.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"19936","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Akahane, K.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"19937","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sato, K.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"19938","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-05-08"}],"displaytype":"detail","filename":"JMS-36-6-578.pdf","filesize":[{"value":"535.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"JMS-36-6-578.pdf","url":"https://kyutech.repo.nii.ac.jp/record/4956/files/JMS-36-6-578.pdf"},"version_id":"0a0b8119-38b0-4b86-96be-88eaba0a7077"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"magneto-optical imaging","subitem_subject_scheme":"Other"},{"subitem_subject":"garnet thin film","subitem_subject_scheme":"Other"},{"subitem_subject":"real time measurement","subitem_subject_scheme":"Other"},{"subitem_subject":"liquid crystal modulator","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Real Time Magneto-optical Imaging using Liquid Crystal Modulator","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Real Time Magneto-optical Imaging using Liquid Crystal Modulator","subitem_title_language":"en"}]},"item_type_id":"21","owner":"3","path":["24"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2017-05-08"},"publish_date":"2017-05-08","publish_status":"0","recid":"4956","relation_version_is_last":true,"title":["Real Time Magneto-optical Imaging using Liquid Crystal Modulator"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2025-07-14T02:40:19.604545+00:00"}