Proposal of New K-factor Function inLightning Impulse Test for Electric Power Equipment

http://hdl.handle.net/10228/00006809
http://hdl.handle.net/10228/00006809
25663976-75ea-4e30-a936-82ab57df0f89
名前 / ファイル ライセンス アクション
ISH2017_128.pdf ISH2017_128.pdf (501.6 kB)
アイテムタイプ 会議発表論文 = Conference Paper(1)
公開日 2018-06-12
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
タイトル
タイトル Proposal of New K-factor Function inLightning Impulse Test for Electric Power Equipment
言語 en
その他のタイトル
その他のタイトル PROPOSAL OF NEW K-FACTOR FUNCTION IN LIGHTNING IMPULSE TEST FOR ELECTRIC POWER EQUIPMENT
言語 en
言語
言語 eng
著者 Okabe, S.

× Okabe, S.

WEKO 22608

en Okabe, S.

Search repository
Ueta, G.

× Ueta, G.

WEKO 22609

en Ueta, G.

Search repository
Tsuboi, T.

× Tsuboi, T.

WEKO 22610

en Tsuboi, T.

Search repository
匹田, 政幸

× 匹田, 政幸

WEKO 3270
Scopus著者ID 7102360870

en Hikita, Masayuki

ja 匹田, 政幸

ja-Kana ヒキタ, マサユキ

Search repository
抄録
内容記述タイプ Abstract
内容記述 Ultra high voltage (UHV) systems are increasingly being planned and constructed, hence studies are promoted on the standard for high-voltage test techniques for UHV-class equipment. For the lightning impulse voltage test, a study is being conducted on the application of a method of evaluating the test waveform through conversion using the test voltage function (k-factor function) that was adopted in IEC 60060-1. The existing k-factor function was established based on the experimental results for more compact models, as compared with the insulating structure of UHV-class equipment, mainly with a breakdown voltage of about 100 kV. To determine whether this k-factor function can also be used for the test of UHV-class equipment, the experimental results for large-sized models were needed. In the present paper, to address this issue, the authors initially obtained k-factor values experimentally using the largest possible model (UHV model) assuming UHV-class equipment. Substantially, a study was conducted on a new k-factor function based on these experimental results. First, in the study, several ideas for the k-factor function were shown and applied to various waveforms to clarify their advantages and disadvantages. Next, in addition to these results, a study was conducted on a k-factor function suitable for UHV-class equipment with considering the actual UHV facilities. Consequently, it was concluded that the form of the function should be the same as that of the existing one but that it would be reasonable to adopt a relatively lower k-factor function for UHV-class equipment by revising the constant. Further, this new function could replace the existing one in 60060-1 for all voltage classes to consider the breakdown voltage ranges as a basis and LIWV (Lightning Impulse Withstand Voltage) values.
備考
内容記述タイプ Other
内容記述 20th International Symposium on High Voltage Engineering, August 28 - September 01, 2017, Buenos Aires, Argentina
書誌情報 20th International Symposium on High Voltage Engineering

発行日 2017-08-27
出版社
出版社 Institute of High Voltage and Power Transmission
著作権関連情報
権利情報 Institute of High Voltage and Power Transmission
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
査読の有無
値 yes
研究者情報
URL https://hyokadb02.jimu.kyutech.ac.jp/html/58_ja.html
論文ID(連携)
値 10318998
連携ID
値 7075
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 14:01:32.645971
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3