WEKO3
アイテム
Temperature rise measurement for power-loss comparison of an aluminum electrolytic capacitor between sinusoidal and square-wave current injections
http://hdl.handle.net/10228/00006910
http://hdl.handle.net/10228/00006910d7d5341e-42ea-4803-8bfe-ce61f51620a4
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
|
| アイテムタイプ | 学術雑誌論文 = Journal Article(1) | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2018-09-20 | |||||||||||||
| 資源タイプ | ||||||||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||
| 資源タイプ | journal article | |||||||||||||
| タイトル | ||||||||||||||
| タイトル | Temperature rise measurement for power-loss comparison of an aluminum electrolytic capacitor between sinusoidal and square-wave current injections | |||||||||||||
| 言語 | en | |||||||||||||
| 言語 | ||||||||||||||
| 言語 | eng | |||||||||||||
| 著者 |
Hasegawa, K.
× Hasegawa, K.× Kozuma, K.× Tsuzaki, K.× 大村, 一郎
WEKO
16176
× Nishizawa, S. |
|||||||||||||
| 抄録 | ||||||||||||||
| 内容記述タイプ | Abstract | |||||||||||||
| 内容記述 | DC-link capacitors are a major factor of degrading reliability of power electric converters because they usually have a shorter lifetime and higher failure rate than those of semiconductor devices or magnetic devices. Characteristics of the capacitors are usually evaluated by a single sinusoidal current waveform. However, actual current flowing out of the converter into the capacitor is a modulated square current waveform. This paper provides experimental comparison of the power loss dissipated in an aluminum electrolytic capacitor between sinusoidal and square-wave current injections. Power loss is estimated by temperature rise of the capacitor. Experimental results confirm that power losses of the square-wave current injection were always lower than those of the sinusoidal current injection by 10–20%. Moreover, the power losses of the square-wave current injection can be estimated by a synthesis of fundamental and harmonic currents based on the Fourier series expansion, which brings a high accuracy less than 1% when more than fifth harmonic current is introduced. This comparison will be useful for estimating power loss and life time of electrolytic capacitors. | |||||||||||||
| 言語 | en | |||||||||||||
| 書誌情報 |
en : Microelectronics Reliability 巻 64, p. 98-100, 発行日 2016-09-18 |
|||||||||||||
| 出版社 | ||||||||||||||
| 出版者 | Elsevier | |||||||||||||
| DOI | ||||||||||||||
| 関連タイプ | isVersionOf | |||||||||||||
| 識別子タイプ | DOI | |||||||||||||
| 関連識別子 | https://doi.org/10.1016/j.microrel.2016.07.049 | |||||||||||||
| ISSN | ||||||||||||||
| 収録物識別子タイプ | PISSN | |||||||||||||
| 収録物識別子 | 0026-2714 | |||||||||||||
| ISSN | ||||||||||||||
| 収録物識別子タイプ | EISSN | |||||||||||||
| 収録物識別子 | 1872-941X | |||||||||||||
| 著作権関連情報 | ||||||||||||||
| 権利情報 | Copyright (c) 2016 Elsevier Ltd | |||||||||||||
| キーワード | ||||||||||||||
| 主題Scheme | Other | |||||||||||||
| 主題 | Aluminum electrolytic capacitors | |||||||||||||
| キーワード | ||||||||||||||
| 主題Scheme | Other | |||||||||||||
| 主題 | DC-link applications | |||||||||||||
| キーワード | ||||||||||||||
| 主題Scheme | Other | |||||||||||||
| 主題 | Inverters | |||||||||||||
| キーワード | ||||||||||||||
| 主題Scheme | Other | |||||||||||||
| 主題 | Power loss | |||||||||||||
| 出版タイプ | ||||||||||||||
| 出版タイプ | AM | |||||||||||||
| 出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||||||||||
| 査読の有無 | ||||||||||||||
| 値 | yes | |||||||||||||
| 連携ID | ||||||||||||||
| 値 | 6099 | |||||||||||||