{"created":"2023-05-15T11:59:25.305982+00:00","id":5824,"links":{},"metadata":{"_buckets":{"deposit":"7411a13f-1414-4a6d-85c0-402240260247"},"_deposit":{"created_by":3,"id":"5824","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"5824"},"status":"published"},"_oai":{"id":"oai:kyutech.repo.nii.ac.jp:00005824","sets":["15:20"]},"author_link":["23839","23837","23836","23840","3665"],"item_23_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-04-11","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicVolumeNumber":"372","bibliographic_titles":[{"bibliographic_title":"IOP Conference Series: Materials Science and Engineering"}]}]},"item_23_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In this paper, the practical analysis methods are proposed for analyzing the singular index and the intensity of singular stress field (ISSF) at the vertex of the interface in the three dimensional (3D) bonded plate. The analysis methods focus FEM stresses at and around the vertex. The singular index is determined from the FEM stress ratio at the vertex obtained by performing FEM analyses on the finely and coarsely meshed models. Then, the ISSF is determined by the ratio of the average FEM stresses at and around the vertex obtained by performing the FEM analyses on the reference and unknown models under the same mesh pattern. The validity of the present methods was examined by the plane strain bonded plate and 3D bonded plate in the literature. It was found that the present methods for the singular index have the same accuracy as the FEM eigenvalue analysis. The asymptotic solutions with the singular index and ISSF by the present method correspond to FEM stress distributions. Since the ISSF by the body force method (BFM) is used as the reference solution, the present method for ISSF has the same accuracy as BFM. Moreover, the critical ISSF values were calculated in the experimental results of the butt joints with various adhesive thicknesses. In the case of the ductile epoxy adhesive, it was shown that the critical ISSF at the vertex by 3D model was more constant against the thickness than that by 2D model. The result is quite different from that of the brittle epoxy adhesive and can be never obtained by 2D model.","subitem_description_type":"Abstract"}]},"item_23_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"2018 International Conference on Material Strength and Applied Mechanics (MSAM 2018), 10–13 April 2018, Kitakyushu City, Japan","subitem_description_type":"Other"}]},"item_23_description_60":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Conference Paper","subitem_description_type":"Other"}]},"item_23_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"23839","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Miyazaki, T."}]},{"nameIdentifiers":[{"nameIdentifier":"23840","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Inoue, T."}]},{"affiliations":[{"affiliationNames":[{"affiliationName":"","lang":"ja"}],"nameIdentifiers":[]}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{"nameIdentifier":"3665","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"40172796","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://nrid.nii.ac.jp/ja/nrid/1000040172796"},{"nameIdentifier":"7202782903","nameIdentifierScheme":"Scopus著者ID","nameIdentifierURI":"https://www.scopus.com/authid/detail.uri?authorId=7202782903"},{"nameIdentifier":"0000-0002-6067-3122","nameIdentifierScheme":"ORCiD","nameIdentifierURI":"https://orcid.org/0000-0002-6067-3122"}],"names":[{"name":"Noda, Nao-Aki","nameLang":"en"},{"name":"野田, 尚昭","nameLang":"ja"},{"name":"ノダ, ナオアキ","nameLang":"ja-Kana"}]}]},"item_23_link_61":{"attribute_name":"研究者情報","attribute_value_mlt":[{"subitem_link_url":"https://hyokadb02.jimu.kyutech.ac.jp/html/10_ja.html"}]},"item_23_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IOP Publishing"}]},"item_23_relation_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"BB19746338 ","subitem_relation_type_select":"NCID"}}]},"item_23_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"info:doi/10.1088/1757-899X/372/1/012002","subitem_relation_type_select":"DOI"}}]},"item_23_relation_14":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://doi.org/10.1088/1757-899X/372/1/012002"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1088/1757-899X/372/1/012002","subitem_relation_type_select":"DOI"}}]},"item_23_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"This is an author-created, un-copyedited version of an article published in IOP Conference Series: Materials Science and Engineering. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. This article is published under a CC BY licence. The Version of Record is available online at https://doi.org/10.1088/1757-899X/372/1/012002.(open access)"}]},"item_23_select_59":{"attribute_name":"査読の有無","attribute_value_mlt":[{"subitem_select_item":"yes"}]},"item_23_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1757-899X","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"1757-8981","subitem_source_identifier_type":"ISSN"}]},"item_23_text_28":{"attribute_name":"論文ID(連携)","attribute_value_mlt":[{"subitem_text_value":"10333855"}]},"item_23_text_37":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"University of the Ryukyus, 1 Senbaru, Nishihara-cho, Nakagami-gun, Okinawa 903-0213, Japan"},{"subitem_text_value":"Graduate School of Engineering and Science, University of the Ryukyus, 1 Senbaru, Nishihara-cho, Nakagami-gun, Okinawa 903-0213, Japan"},{"subitem_text_value":"Kyushu Institute of Technology, 1-1 Sensui-cho, Tobata-ku, Kitakyushu-shi, Fukuoka 804-8550, Japan"}]},"item_23_text_62":{"attribute_name":"連携ID","attribute_value_mlt":[{"subitem_text_value":"7541"}]},"item_23_version_type_58":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Miyazaki, Tatsujiro"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Inoue, Takuma"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"Noda, Nao-Aki","creatorNameLang":"en"},{"creatorName":"野田, 尚昭","creatorNameLang":"ja"},{"creatorName":"ノダ, ナオアキ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-02-19"}],"displaytype":"detail","filename":"1757-899X_372_1_012002.pdf","filesize":[{"value":"926.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"1757-899X_372_1_012002.pdf","url":"https://kyutech.repo.nii.ac.jp/record/5824/files/1757-899X_372_1_012002.pdf"},"version_id":"c18f5308-5a28-48c6-93a5-914a84f15c47"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Practical method for analyzing singular index and intensity of singular stress field for three dimensional bonded plate","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Practical method for analyzing singular index and intensity of singular stress field for three dimensional bonded plate"}]},"item_type_id":"23","owner":"3","path":["20"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-02-19"},"publish_date":"2019-02-19","publish_status":"0","recid":"5824","relation_version_is_last":true,"title":["Practical method for analyzing singular index and intensity of singular stress field for three dimensional bonded plate"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-10-25T06:46:59.554381+00:00"}