{"created":"2023-05-15T11:59:53.403616+00:00","id":6509,"links":{},"metadata":{"_buckets":{"deposit":"35c6f731-eaa5-4962-9686-a956be44f92b"},"_deposit":{"created_by":3,"id":"6509","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"6509"},"status":"published"},"_oai":{"id":"oai:kyutech.repo.nii.ac.jp:00006509","sets":["8:9"]},"author_link":["27506","27508","27510","27512","27516","27509","27505","27511","27504"],"control_number":"6509","item_21_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-09-04","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"876","bibliographicPageStart":"875","bibliographicVolumeNumber":"2019","bibliographic_titles":[{"bibliographic_title":"精密工学会学術講演会講演論文集"}]}]},"item_21_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"近年,チューブ型の内視鏡とカプセル内視鏡に代わる検査方法として自走可能なカプセル内視鏡の研究が進められている.このカプセルは蠕動運動に依らず移動可能であり,短時間で腸内を検査することが可能である.これまでの小腸用カプセル内視鏡に比べ,駆動力の大きい大腸用カプセル内視鏡の提案をする.走行機構の大型化により駆動力を向上させている.大腸用カプセル内視鏡の走行実験を行い,走行性能の評価を行った.","subitem_description_type":"Abstract"}]},"item_21_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"2019年度精密工学会春季大会, 2019年3月13-15日, 東京電機大学","subitem_description_type":"Other"}]},"item_21_description_60":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Journal Article","subitem_description_type":"Other"}]},"item_21_link_62":{"attribute_name":"研究者情報","attribute_value_mlt":[{"subitem_link_url":"https://hyokadb02.jimu.kyutech.ac.jp/html/249_ja.html"}]},"item_21_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"精密工学会"}]},"item_21_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.11522/pscjspe.2019S.0_875","subitem_relation_type_select":"DOI"}}]},"item_21_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright (c) 2019 公益社団法人 精密工学会"}]},"item_21_select_59":{"attribute_name":"査読の有無","attribute_value_mlt":[{"subitem_select_item":"no"}]},"item_21_text_28":{"attribute_name":"論文ID(連携)","attribute_value_mlt":[{"subitem_text_value":"10351404"}]},"item_21_text_36":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"九州工業大学"},{"subitem_text_value":"九州工業大学"},{"subitem_text_value":"九州工業大学"},{"subitem_text_value":"九州工業大学"},{"subitem_text_value":"九州工業大学"},{"subitem_text_value":"東京農工大学"},{"subitem_text_value":"東京農工大学"},{"subitem_text_value":"東京農工大学"},{"subitem_text_value":"株式会社ロジカルプロダクト"}]},"item_21_text_63":{"attribute_name":"連携ID","attribute_value_mlt":[{"subitem_text_value":"8211"}]},"item_21_version_type_58":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"浅井, 謙太","creatorNameLang":"ja"},{"creatorName":"Asai, Kenta","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"渡邉, 翔太朗","creatorNameLang":"ja"},{"creatorName":"Watanabe, Syotaro","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"一木, 浩之","creatorNameLang":"ja"},{"creatorName":"Ichiki, Hiroyuki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"Ito, Takahiro","creatorNameLang":"en"},{"creatorName":"伊藤, 高廣","creatorNameLang":"ja"},{"creatorName":"イトウ, タカヒロ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{},{},{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"Murakami, Sunao","creatorNameLang":"en"},{"creatorName":"村上, 直","creatorNameLang":"ja"},{"creatorName":"ムラカミ, スナオ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"勝田, ちひろ","creatorNameLang":"ja"},{"creatorName":"Katsuta, Chihiro","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"田中, あかね","creatorNameLang":"ja"},{"creatorName":"Tanaka, Akane","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"松田, 浩珍","creatorNameLang":"ja"},{"creatorName":"Matsuda, Hiroshi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"辻, 卓則","creatorNameLang":"ja"},{"creatorName":"Tsuji, Takunori","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-04-21"}],"displaytype":"detail","filename":"pscjspe.2019S.0_875.pdf","filesize":[{"value":"556.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"pscjspe.2019S.0_875.pdf","url":"https://kyutech.repo.nii.ac.jp/record/6509/files/pscjspe.2019S.0_875.pdf"},"version_id":"577e64f9-9dda-4103-a79e-cc9cd6e35597"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"カプセル","subitem_subject_scheme":"Other"},{"subitem_subject":"マイクロメカニズム","subitem_subject_scheme":"Other"},{"subitem_subject":"内視鏡","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"大腸用自走式カプセル内視鏡の走行性能に関する研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"大腸用自走式カプセル内視鏡の走行性能に関する研究","subitem_title_language":"ja"},{"subitem_title":"Impulse-driven capsule for colorectal inspection","subitem_title_language":"en"}]},"item_type_id":"21","owner":"3","path":["9"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2020-04-21"},"publish_date":"2020-04-21","publish_status":"0","recid":"6509","relation_version_is_last":true,"title":["大腸用自走式カプセル内視鏡の走行性能に関する研究"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2024-04-02T08:33:52.112603+00:00"}