{"created":"2023-05-15T12:00:30.123959+00:00","id":7324,"links":{},"metadata":{"_buckets":{"deposit":"1baf526b-8da4-4f6d-9a42-f77e9928d7d8"},"_deposit":{"created_by":3,"id":"7324","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"7324"},"status":"published"},"_oai":{"id":"oai:kyutech.repo.nii.ac.jp:00007324","sets":["8:24"]},"author_link":["31680","31681","31450","31679"],"item_21_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2004-06-01","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"140","bibliographicPageStart":"137","bibliographic_titles":[{"bibliographic_title":"2004 International Symposium on Electromagnetic Compatibility"}]}]},"item_21_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The equipment under test (EUT) was modeled by current sources. The current positions were estimated using the finding method of radiated emission source by electric field strength data alone. The current vectors were determined by the conditions, where Norm (deviation between the calculated electric field and the measured one) was minimized. Using estimated current sources model, the electric filed strength at 10m distance was predicted. The predicted results were compared with the measured data for an imitated equipment and a personal computer. The results indicate that the radiation patterns were similar to the measured ones, and the maximum electric field strength at10m distance was comparable to the measured value and the calculated value on the assumption where electric field decreases in proportion to distance.","subitem_description_type":"Abstract"}]},"item_21_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"2004 International Symposium on Electromagnetic Compatibility (EMC'04/Sendai), June 1-4, 2004, Sendai International Center, Sendai, Japan","subitem_description_type":"Other"}]},"item_21_description_60":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Journal Article","subitem_description_type":"Other"}]},"item_21_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"電子情報通信学会"}]},"item_21_relation_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"BA74414047","subitem_relation_type_select":"NCID"}}]},"item_21_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.34385/proc.11.1C3-1","subitem_relation_type_select":"DOI"}}]},"item_21_relation_9":{"attribute_name":"ISBN","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"4-88552-203-X","subitem_relation_type_select":"ISBN"}}]},"item_21_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright(C)2004 IEICE"}]},"item_21_subject_16":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"547","subitem_subject_scheme":"NDC"}]},"item_21_text_36":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"Department of Electrical Engineering, Kyushu Institute of Technology, Kitakyushu, Japan"},{"subitem_text_value":"Fukuoka Industrial Technology Center, Kitakyushu, Japan"},{"subitem_text_value":"ADOX Fukuoka, Nogata, Japan"},{"subitem_text_value":"Department of Electrical Engineering, Kyushu Institute of Technology, Kitakyushu, Japan"}]},"item_21_text_63":{"attribute_name":"連携ID","attribute_value_mlt":[{"subitem_text_value":"9751"}]},"item_21_version_type_58":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Aoki, Noburo"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kawabata, Masato"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ishida, Yasuhiro"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"Kuwabara, Nobuo","creatorNameLang":"en"},{"creatorName":"桑原, 伸夫","creatorNameLang":"ja"},{"creatorName":"クワバラ, ノブオ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-11-11"}],"displaytype":"detail","filename":"EMC_proc.11.1C3-1.pdf","filesize":[{"value":"418.5 kB"}],"format":"application/octet-stream","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"EMC_proc.11.1C3-1.pdf","url":"https://kyutech.repo.nii.ac.jp/record/7324/files/EMC_proc.11.1C3-1.pdf"},"version_id":"612ab5e6-054a-4d82-ad83-b139e20f8cd7"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Finding method of radiated emission source","subitem_subject_scheme":"Other"},{"subitem_subject":"Prediction electric field strength","subitem_subject_scheme":"Other"},{"subitem_subject":"EUT modeling","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Prediction of Electric Field Strength at 10m Distance Using Emission Source Finding Method","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Prediction of Electric Field Strength at 10m Distance Using Emission Source Finding Method"}]},"item_type_id":"21","owner":"3","path":["24"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-11-11"},"publish_date":"2021-11-11","publish_status":"0","recid":"7324","relation_version_is_last":true,"title":["Prediction of Electric Field Strength at 10m Distance Using Emission Source Finding Method"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-10-25T09:49:49.111087+00:00"}