{"_buckets": {"deposit": "c4245ad9-c273-407f-9ad0-ad2103ac4a37"}, "_deposit": {"created_by": 3, "id": "1532", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "1532"}, "status": "published"}, "_oai": {"id": "oai:kyutech.repo.nii.ac.jp:00001532", "sets": ["20"]}, "author_link": ["28962", "6157", "27516"], "item_23_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007", "bibliographicIssueDateType": "Issued"}, "bibliographic_titles": [{}]}]}, "item_23_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We have developed1 a traveling small capsule, which has a smooth outer surface and is driven by inertia force and friction force. Measuring only 7 mm in diameter and 12 mm in length, it is sufficiently small to be placed in the human gullet or intestines. The capsule contains a small magnet and a coil, and an electric pulse drives the magnet to move the capsule. To investigate the feasibility of our traveling capsule, we conducted theoretical analyses using a simple model. Separating the phenomena into four steps, we obtained fundamental equations and clarified the motion. We performed an experimental investigation on making our capsule travel on a plastic material, which has similar elasticity characteristics to the living body. We also showed that it can travel on the surface of a pig’s intestine. We measured the temperature of the capsule during its movement to evaluate safety for the human body. Using the calculated results, we created a new input signal pattern for the capsule and thus successfully doubled the speed of movement of the capsule. Our capsule may be useful for medical treatments such as inspection, drug delivery and operation.", "subitem_description_type": "Abstract"}]}, "item_23_description_5": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "12th lFTOMM World Congress, Besancon, France, 2007.", "subitem_description_type": "Other"}]}, "item_23_description_60": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "Conference Paper", "subitem_description_type": "Other"}]}, "item_23_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "27516", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "10367401", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000010367401/"}, {"nameIdentifier": "55471019200", "nameIdentifierScheme": "Scopus著者ID", "nameIdentifierURI": "https://www.scopus.com/authid/detail.uri?authorId=55471019200"}, {"nameIdentifier": "249", "nameIdentifierScheme": "九工大研究者情報", "nameIdentifierURI": "https://hyokadb02.jimu.kyutech.ac.jp/html/249_ja.html"}], "names": [{"name": "伊藤, 高廣"}]}]}, "item_23_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "lFTOMM World Congress"}]}, "item_23_text_37": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "Toin University of Yokohama, Kanagawa, Japan"}, {"subitem_text_value": "Toin University of Yokohama, Kanagawa, Japan"}, {"subitem_text_value": "Ogasawara Precision Laboratory, Kanagawa, Japan"}]}, "item_23_text_63": {"attribute_name": "業績ID", "attribute_value_mlt": [{"subitem_text_value": "44AB2027B05DC93C49257593003465EF"}]}, "item_23_version_type_58": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Ito, Takahiro"}], "nameIdentifiers": [{"nameIdentifier": "27516", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "10367401", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000010367401/"}, {"nameIdentifier": "55471019200", "nameIdentifierScheme": "Scopus著者ID", "nameIdentifierURI": "https://www.scopus.com/authid/detail.uri?authorId=55471019200"}, {"nameIdentifier": "249", "nameIdentifierScheme": "九工大研究者情報", "nameIdentifierURI": "https://hyokadb02.jimu.kyutech.ac.jp/html/249_ja.html"}]}, {"creatorNames": [{"creatorName": "Ogushi, Takuto"}], "nameIdentifiers": [{"nameIdentifier": "6157", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hayashi, Teru"}], "nameIdentifiers": [{"nameIdentifier": "28962", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2009-04-09"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "3_A495.pdf", "filesize": [{"value": "318.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 318100.0, "url": {"label": "3_A495.pdf", "url": "https://kyutech.repo.nii.ac.jp/record/1532/files/3_A495.pdf"}, "version_id": "378eef69-059a-4fa8-a8b5-64f5250c0654"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "micromechanism", "subitem_subject_scheme": "Other"}, {"subitem_subject": "friction force", "subitem_subject_scheme": "Other"}, {"subitem_subject": "magnetic force", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "lmpulse-driven Capsule by Coil-induced Magnetic Field lmplementation", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "lmpulse-driven Capsule by Coil-induced Magnetic Field lmplementation"}]}, "item_type_id": "23", "owner": "3", "path": ["20"], "permalink_uri": "http://hdl.handle.net/10228/2361", "pubdate": {"attribute_name": "公開日", "attribute_value": "2009-04-09"}, "publish_date": "2009-04-09", "publish_status": "0", "recid": "1532", "relation": [{"item_links": "1564", "item_title": "lmpulse-driven Capsule by Coil-induced Magnetic Field lmplementation", "value": "relateTo"}], "relation_version_is_last": true, "title": ["lmpulse-driven Capsule by Coil-induced Magnetic Field lmplementation"], "weko_shared_id": 3}
  1. 学会・会議発表論文
  2. 学会・会議発表論文

lmpulse-driven Capsule by Coil-induced Magnetic Field lmplementation

http://hdl.handle.net/10228/2361
http://hdl.handle.net/10228/2361
a74fdc53-e24c-466c-a532-024e100ab60b
名前 / ファイル ライセンス アクション
3_A495.pdf 3_A495.pdf (318.1 kB)
Item type 会議発表論文 = Conference Paper(1)
公開日 2009-04-09
タイトル
タイトル lmpulse-driven Capsule by Coil-induced Magnetic Field lmplementation
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
著者 Ito, Takahiro

× Ito, Takahiro

WEKO 27516
e-Rad 10367401
Scopus著者ID 55471019200
九工大研究者情報 249

Ito, Takahiro

Search repository
Ogushi, Takuto

× Ogushi, Takuto

WEKO 6157

Ogushi, Takuto

Search repository
Hayashi, Teru

× Hayashi, Teru

WEKO 28962

Hayashi, Teru

Search repository
著者別名
姓名 伊藤, 高廣
抄録
内容記述タイプ Abstract
内容記述 We have developed1 a traveling small capsule, which has a smooth outer surface and is driven by inertia force and friction force. Measuring only 7 mm in diameter and 12 mm in length, it is sufficiently small to be placed in the human gullet or intestines. The capsule contains a small magnet and a coil, and an electric pulse drives the magnet to move the capsule. To investigate the feasibility of our traveling capsule, we conducted theoretical analyses using a simple model. Separating the phenomena into four steps, we obtained fundamental equations and clarified the motion. We performed an experimental investigation on making our capsule travel on a plastic material, which has similar elasticity characteristics to the living body. We also showed that it can travel on the surface of a pig’s intestine. We measured the temperature of the capsule during its movement to evaluate safety for the human body. Using the calculated results, we created a new input signal pattern for the capsule and thus successfully doubled the speed of movement of the capsule. Our capsule may be useful for medical treatments such as inspection, drug delivery and operation.
内容記述
内容記述タイプ Other
内容記述 12th lFTOMM World Congress, Besancon, France, 2007.
書誌情報 発行日 2007
出版者
出版者 lFTOMM World Congress
キーワード
主題Scheme Other
主題 micromechanism
キーワード
主題Scheme Other
主題 friction force
キーワード
主題Scheme Other
主題 magnetic force
版
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
リンク lmpulse-driven Capsule by Coil-induced Magnetic Field lmplementation
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 13:28:09.272505
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3