ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学術雑誌論文
  2. 5 技術(工学)

Bioactive polymethylmethacrylate bone cement modified with combinations of phosphate group-containing monomers and calcium acetate

http://hdl.handle.net/10228/5536
http://hdl.handle.net/10228/5536
c6082ff4-393d-4b19-8998-546d756f43ca
名前 / ファイル ライセンス アクション
JBA_29_1296.pdf JBA_29_1296.pdf (712.9 kB)
アイテムタイプ 学術雑誌論文 = Journal Article(1)
公開日 2016-01-05
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
タイトル
タイトル Bioactive polymethylmethacrylate bone cement modified with combinations of phosphate group-containing monomers and calcium acetate
言語 en
その他のタイトル
その他のタイトル Bioactive PMMA bone cement modified with combinations of phosphate group-containing monomers and calcium acetate
言語 en
言語
言語 eng
著者 Liu, Jinkun

× Liu, Jinkun

WEKO 15663

en Liu, Jinkun

Search repository
城崎, 由紀

× 城崎, 由紀

WEKO 15664
e-Rad 40533956
Scopus著者ID 6507486862
ORCiD 0000-0003-4207-4393
九工大研究者情報 100000586

en Shirosaki, Yuki

ja 城崎, 由紀

ja-Kana シロサキ, ユキ


Search repository
宮崎, 敏樹

× 宮崎, 敏樹

WEKO 6369
e-Rad 20324973
Scopus著者ID 7404107414
ORCiD 0000-0001-5642-0096
九工大研究者情報 323

en Miyazaki, Toshiki

ja 宮崎, 敏樹

ja-Kana ミヤザキ, トシキ


Search repository
抄録
内容記述タイプ Abstract
内容記述 Bone cement from polymethylmethacrylate powder and methylmethacrylate liquid has been successfully demonstrated as artificial material to anchor joint replacements in bone. However, it lacks the capability to bond directly to bone, so long-term implantation leads to an increased risk of loosening. Bioactive materials show better performance in fixation to bone, and the chemical bonding depends on bone-like apatite formation. This is triggered by surface reactions with body fluid. For these reactions, superficial functional groups like silanol (Si–OH) are ideal sites to induce apatite nucleation and the release of Ca2+ ions accelerates the apatite growth. Therefore, incorporation of materials containing these key components may provide the cement with apatite-forming ability. In this study, phosphoric acid 2-hydroxyethyl methacrylate ester or bis[2-(methacryloyloxy)ethyl] phosphate supplying a phosphate group (PO4H2) was added into methylmethacrylate liquid, while calcium acetate as a source of Ca2+ ions was mixed into polymethylmethacrylate powder. The influences of the combinations on the setting time and compressive strength were also investigated. Apatite was formed on the cements modified with 30 mass% of phosphoric acid 2-hydroxyethyl methacrylate ester or bis[2-(methacryloyloxy)ethyl] phosphate. The induction period was shortened with increased amounts of Ca(CH3COO)2. The setting time could be controlled by the Ca(CH3COO)2/monomer mass ratio. Faster setting was achieved at a ratio close to the mixing ratio of the powder/liquid (2:1), and both increases and decreases in the amount of Ca(CH3COO)2 prolonged the setting time based on this ratio. The highest compressive strength was 88.8 ± 2.6 MPa, higher than the lowest limit of ISO 5833 but was lower than that of the simulated body fluid-soaked reference. The increase of additives caused the decline in compressive strength. In view of balancing apatite formation and clinical standard, bis[2-(methacryloyloxy)ethyl] phosphate is more suitable as an additive, and the optimal modification is a combination of 30 mass% of bis[2-(methacryloyloxy)ethyl] phosphate and 20 mass% of Ca(CH3COO)2.
言語 en
書誌情報 en : Journal of Biomaterials Applications

巻 29, 号 9, p. 1296-1303, 発行日 2015-04-01
出版社
出版者 Sage Publications
言語 en
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1177/0885328214562436
ISSN
収録物識別子タイプ PISSN
収録物識別子 0885-3282
ISSN
収録物識別子タイプ EISSN
収録物識別子 1530-8022
著作権関連情報
権利情報 Sage Publications
キーワード
主題Scheme Other
主題 Bioactive PMMA bone cement
キーワード
主題Scheme Other
主題 Phosphate group-containing monomers
キーワード
主題Scheme Other
主題 Calcium acetate
キーワード
主題Scheme Other
主題 Compressive strength
キーワード
主題Scheme Other
主題 Simulated body fluid (SBF)
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
査読の有無
値 yes
研究者情報
URL https://hyokadb02.jimu.kyutech.ac.jp/html/323_ja.html
連携ID
値 5262
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 13:46:52.932726
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3