ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学術雑誌論文
  2. 5 技術(工学)

Thermal Response Analysis of Low-Density CFRP Ablator

http://hdl.handle.net/10228/00007628
http://hdl.handle.net/10228/00007628
58c69eb2-5f1d-40ef-b7c1-50e2cbbfe466
名前 / ファイル ライセンス アクション
LaSEINE-2012_02.pdf LaSEINE-2012_02.pdf (4.8 MB)
Item type 学術雑誌論文 = Journal Article(1)
公開日 2020-02-20
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
タイトル
タイトル Thermal Response Analysis of Low-Density CFRP Ablator
言語
言語 eng
著者 Suzuki, Toshiyuki

× Suzuki, Toshiyuki

WEKO 26887

Suzuki, Toshiyuki

Search repository
Fujita, Kazuhisa

× Fujita, Kazuhisa

WEKO 26888

Fujita, Kazuhisa

Search repository
Sakai, Takeharu

× Sakai, Takeharu

WEKO 26889

Sakai, Takeharu

Search repository
Okuyama, Kei-ichi

× Okuyama, Kei-ichi

WEKO 26890

Okuyama, Kei-ichi

Search repository
Kato, Sumio

× Kato, Sumio

WEKO 26891

Kato, Sumio

Search repository
Nishio, Seiji

× Nishio, Seiji

WEKO 26892

Nishio, Seiji

Search repository
抄録
内容記述タイプ Abstract
内容記述 The thermal characteristics of the low-density ablator are quantified by conducting the heating tests of materials in an arcjet wind tunnel. In the tests, test pieces of the ablator with a diameter of 40 mm and a length of 58 mm are put into arcjet flow. The arcjet wind tunnel is run for two sets of operational condition: a low heating condition for the heat flux of 0.97 MW/m2 and the impact pressure of 1.93 kPa, and a high heating one for 1.97 MW/m2 and 4.25 kPa, respectively. The surface temperature and in-depth temperature are measured during the testing. The surface shape changes of ablator and the amount of mass loss of ablator are measured after the heating tests. The obtained experimental data are analyzed by using an integrated computational method developed earlier. Agreement between the calculations and the heating tests are excellent in the comparison of the surface shape changes of ablative test pieces. The temporal variations of surface temperature are also well reproduced by the present numerical method within the experimental error. However, the calculation underestimates the in-depth temperatures and the amount of mass loss of ablative test piece. The reason for this discrepancy may come from the lack of the thermal conductivity data especially in high temperature range above 500K. In addition, the present study suggests that the thermal conduction of the ablative test piece used in this study could be anisotropic to some extent.
備考
内容記述タイプ Other
内容記述 28th International Symposium on Space Technology and Science (28th ISTS), 5-12 June 2011, Okinawa, Japan
書誌情報 Transactions of the Japan Society for Aeronautical and Space Sciences, Aerospace Technology Japan

巻 10, 号 ists28, p. Pe_21-Pe_30, 発行日 2012-06-11
出版社
出版者 日本航空宇宙学会
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 https://doi.org/10.2322/tastj.10.Pe_21
ISSN
収録物識別子タイプ ISSN
収録物識別子 1884-0485
著作権関連情報
権利情報 Copyright (c) 2012 The Japan Society for Aeronautical and Space Sciences
キーワード
主題Scheme Other
主題 Low Density Ablator
キーワード
主題Scheme Other
主題 Heating Tests
キーワード
主題Scheme Other
主題 Numerical Analysis
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
査読の有無
値 yes
連携ID
値 7987
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 13:40:17.024247
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3