Development of catheter-type tactile sensor composed of polyvinylidene fluoride (PVDF) film
http://hdl.handle.net/10228/00007536
http://hdl.handle.net/10228/00007536e8e1cdba-043d-46f3-9e4b-ca3ee0ff34b7
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
|
| アイテムタイプ | 学術雑誌論文 = Journal Article(1) | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2020-01-16 | |||||||||||||
| 資源タイプ | ||||||||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||
| 資源タイプ | journal article | |||||||||||||
| タイトル | ||||||||||||||
| タイトル | Development of catheter-type tactile sensor composed of polyvinylidene fluoride (PVDF) film | |||||||||||||
| 言語 | en | |||||||||||||
| 言語 | ||||||||||||||
| 言語 | eng | |||||||||||||
| 著者 |
髙嶋, 一登
× 髙嶋, 一登
WEKO
26196
× Ota, Keisuke× Yamamoto, Masaki× Takenaka, Makoto× Horie, Satoshi× Ishida, Kenji |
|||||||||||||
| 抄録 | ||||||||||||||
| 内容記述タイプ | Abstract | |||||||||||||
| 内容記述 | To achieve quantitative palpation in vivo, we developed a catheter-type tactile sensor composed of a polyvinylidene fluoride film for minimally invasive surgery. We evaluated the fundamental performance of the prototype sensor by a weight-drop test. We also measured the output of the prototype sensor as it was inserted into a blood vessel model with shapes mimicking lesions. The ø2-mm sensor passed easily into the blood vessel model with lesion-like shapes. Sensor outputs corresponded to the shape of the inner wall of the blood vessel model, making it possible to determine the position of a protrusion and the convexity interval of a rough surface by filtering and frequency analysis of the output. | |||||||||||||
| 言語 | en | |||||||||||||
| 書誌情報 |
en : ROBOMECH Journal 巻 6, 号 19, 発行日 2019-12-16 |
|||||||||||||
| 出版社 | ||||||||||||||
| 出版者 | SpringerOpen | |||||||||||||
| DOI | ||||||||||||||
| 関連タイプ | isIdenticalTo | |||||||||||||
| 識別子タイプ | DOI | |||||||||||||
| 関連識別子 | https://doi.org/10.1186/s40648-019-0147-9 | |||||||||||||
| 日本十進分類法 | ||||||||||||||
| 主題Scheme | NDC | |||||||||||||
| 主題 | 492 | |||||||||||||
| ISSN | ||||||||||||||
| 収録物識別子タイプ | EISSN | |||||||||||||
| 収録物識別子 | 2197-4225 | |||||||||||||
| 著作権関連情報 | ||||||||||||||
| 権利情報Resource | http://creativecommons.org/licenses/by/4.0/ | |||||||||||||
| 権利情報 | Copyright (c) The Author(s) 2019. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. | |||||||||||||
| キーワード | ||||||||||||||
| 主題Scheme | Other | |||||||||||||
| 主題 | Tactile sensor | |||||||||||||
| キーワード | ||||||||||||||
| 主題Scheme | Other | |||||||||||||
| 主題 | Polyvinylidene fluoride film | |||||||||||||
| キーワード | ||||||||||||||
| 主題Scheme | Other | |||||||||||||
| 主題 | Organic ferroelectrics | |||||||||||||
| キーワード | ||||||||||||||
| 主題Scheme | Other | |||||||||||||
| 主題 | Palpation | |||||||||||||
| キーワード | ||||||||||||||
| 主題Scheme | Other | |||||||||||||
| 主題 | Piezoresponse | |||||||||||||
| キーワード | ||||||||||||||
| 主題Scheme | Other | |||||||||||||
| 主題 | Catheter | |||||||||||||
| 出版タイプ | ||||||||||||||
| 出版タイプ | VoR | |||||||||||||
| 出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||||||
| 査読の有無 | ||||||||||||||
| 値 | yes | |||||||||||||
| 研究者情報 | ||||||||||||||
| URL | https://hyokadb02.jimu.kyutech.ac.jp/html/328_ja.html | |||||||||||||
| 論文ID(連携) | ||||||||||||||
| 値 | 10348941 | |||||||||||||
| 連携ID | ||||||||||||||
| 値 | 8042 | |||||||||||||